Abstract

District heating enables an economical use of energy sources that would otherwise be wasted to cover the heating demands of buildings in urban areas. For efficient utilization of local waste heat and renewable heat sources, low distribution temperatures are of crucial importance. This study evaluates a local heating network being planned for a new building area in Trondheim, Norway, with waste heat available from a nearby ice skating rink. Two alternative supply temperature levels have been evaluated with dynamic simulations: low temperature (40 °C), with direct utilization of waste heat and decentralized domestic hot water (DHW) production using heat pumps; and medium temperature (70 °C), applying a centralized heat pump to lift the temperature of the waste heat. The local network will be connected to the primary district heating network to cover the remaining heat demand. The simulation results show that with a medium temperature supply, the peak power demand is up to three times higher than with a low temperature supply. This results from the fact that the centralized heat pump lifts the temperature for the entire network, including space and DHW heating demands. With a low temperature supply, heat pumps are applied only for DHW production, which enables a low and even electricity demand. On the other hand, with a low temperature supply, the district heating demand is high in the wintertime, in particular if the waste heat temperature is low. The choice of a suitable supply temperature level for a local heating network is hence strongly dependent on the temperature of the available waste heat, but also on the costs and emissions related to the production of district heating and electricity in the different seasons.

Highlights

  • Heating and cooling in buildings and industry account for approximately 40% of the global final energy demand [1]

  • The aim of this study is to reveal the advantages and disadvantages of the two supply temperature alternatives in terms of heat and electricity use, considering both heat import from the primary District heating (DH) network as well as electricity required for circulation pumps and compressors of the heat pumps

  • The total domestic hot water (DHW) demand shown for the low temperature (LT) case is the heat supplied to the heat pump evaporator

Read more

Summary

Introduction

Heating and cooling in buildings and industry account for approximately 40% of the global final energy demand [1]. The increasing degree of urbanization promotes the utilization of collective heating solutions; in Europe, approximately 50% of the buildings’ heat demands could be economically met using a network heating system [3,4]. District heating (DH) may play a central role in the future fossil-free, smart energy systems [5,6]. A prerequisite for this is a transition from today’s high temperature DH systems relying on centralized heat supply plants towards lower distribution temperatures and a higher share of decentralized heat production based on renewable and waste heat sources [4,5,7].

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call