The dependence of the loading (L) factor on the Weibull modulus (m) was derived for the biaxial flexure test assuming a 2‐parameter Weibull stress function and noninteracting orthogonal stresses. The specimen and test fiture dimensions influence the dependence significantly, whereas little difference is found between a 3‐point or ring specimen support. The L factors are more strongly influenced by the Weibull modulus than in a 3‐point bend test.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.