Abstract
To reduce the energy use of the European building stock, a large potential can be found in the renovation of cultural heritage buildings. However, insulating these valuable masonry facades often increases the risk of moisture-related damage phenomena such as mold growth and frost damage. Therefore, detailed heat, air and moisture simulations are required to quantify and assess these risks. One of the unknown parameters in the simulations for historic masonries is the hygric interface resistance between the bricks and the lime mortars. Consequently, microfocus X-ray scans are performed during a capillary water absorption test on brick–lime mortar–brick samples to increase the insight into the moisture transport over the interface, dependent on the capillary pressure at the interface and the curing conditions of the mortar. The hygric interface resistance is found to be highly dependent on both capillary pressure and the curing conditions of the mortar. For the exact quantification of the interface resistance, highly detailed moisture transport and moisture storage properties of the brick and mortar are a prerequisite.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.