Abstract

Membranes from different commercial polymers (Trogamid® and Radel®) and a new (PAA-g-PEG550) copolymer, consisting of an aromatic polyamide modified with PEG, have been prepared with pore sizes from 0.4μm to 8nm. Their porosimetric features have been analyzed by liquid–liquid displacement porometry. In all cases narrower pores are obtained when the polymer concentration in the casting solution increases. Good accordance with image analysis pore sizes is noted. Good correlation is also detected when air–liquid porometry can be used.Permeability decreases always with increasing polymer concentration. Porosity increases when finger like structures are obtained (Trogamid® and PAA-g-PEG550); while, when granular structures are obtained (Radel®), porosity decreases when more polymer is used in the casting procedure.The membrane manufactured from the experimental polymer PAA-g-PEG550 shows high permeabilities and porosities with simultaneous low pore sizes and narrow pore size distributions. The molecular weight cut-off estimated by liquid–liquid porometry agrees well with that found by PEG retention experiments.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.