Abstract

AbstractCost‐efficient operation of inland brackish water reverse osmosis (BWRO) demands a high recovery. As recovery of BWRO is often limited to scaling, antiscalants (AS) are applied, whose environmental impact is disputed. In this paper, different systems (conventional single‐ and two‐stage plug flow RO (PFRO) and closed‐circuit RO (CCRO)) were simulated in various configurations (AS dosing, ion exchange (IEX) pretreatment, elements per vessel) to determine the recovery limiting factor for a hard feed. The novel proposed IEX‐CCRO reached the highest recovery without AS dosing. PFRO configurations had lower recoveries, mainly due to hydraulic limitations. Utilizing RO brine reduced both the water demand and salts necessary for IEX regeneration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.