Abstract

Options to reinforce or reconstruct the corpora cavernosa during penile prosthesis surgery are limited. Synthetic grafts may confer a higher infection risk. Lightweight macroporous mesh is a promising alternative due to better integration and tissue ingrowth. The study sought to report the first experience of using lightweight mesh to reinforce or reconstruct the corpora. The medical records of all patients undergoing insertion or revision of penile prosthesis between May 2016 and May 2021 were reviewed retrospectively. Patient characteristics, management, and outcomes were extracted in which mesh was used for corporal reconstruction. Poliglecaprone-25/polypropylene mesh (UltraPro) was used in all cases. The surgical technique and alternatives were summarized. The outcomes were infection rate, postoperative complications by Clavien-Dindo classification, and patient-reported outcomes. Mesh was required during penile prosthesis surgery in 21 men (median age 56 [range, 18-74] years). Reasons for reconstruction were severe corporal fibrosis (n = 6), impending erosion (n = 6), crossover/perforation (n = 6), congenital corporal agenesis (n = 2), and excision of Peyronie's plaque. All but 2 patients (with corporal agenesis) presented for revision penile prosthesis surgery with a median number of previous revision attempts of 2 (range, 1-5). Two (10%) patients required explant after a mean follow-up of 23 ± 8.7 months. One man developed infection of the device 2years after surgery, translating to an infection rate of 5% despite a high prevalence of diabetes (25%) in this cohort. Another required explantation due to debilitating chronic pain after 3months. Further revision surgery for stiction syndrome was required in a third patient. Finally, another man was not satisfied with the position of the pump within the scrotum or the axial rigidity of the device, despite a second opinion suggesting no issues with the device. All men were sexually active following surgery. A lightweight mesh can be considered to reinforce or reconstruct the corpora cavernosa in complex cases in which there are no alternative techniques available. This is the first study using a lightweight macroporous mesh for revision penile prosthesis surgery. This was a well-characterized cohort of patients. A larger cohort with 5-year follow-up would be preferable. These early results suggest that a lightweight macroporous mesh may be an acceptable synthetic graft for corporal reconstruction. Poliglecaprone-25/polypropylene mesh may be ideal because it is partially absorbable, easy to handle, and not bulky.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.