Abstract
A 1000-h steady state life test at a temperature of 125°C was performed on ten X-band MMIC multifunction chips for use in active phase array radar systems. Internal switches, phase shifters, and attenuators were operated through an integrated serial-to-parallel converter under the five-second stepped external control signal for the life test period. None of the ten samples failed under the failure criteria based on the JEP118 standard. The calculated failure rate using the Chi Square Statistic was 1.6e−6 failures/h for the 90% confidence level. Maximum DC current variation was +16% for an initial value. Maximum variations of small signal gain, phase shift, and attenuation were 0.96dB, 2°, and 0.17dB, respectively, over a frequency range of 8.5–10.5GHz.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.