Abstract
Abstract Background Formulation screening is essential to experimentally balance stability and viscosity in high-concentration mAb formulations. We developed a high-throughput approach with automated sample preparation and analytical workflows to enable the integrated assessment of excipient compatibility and viscosity of mAb formulations. Methods Ninety-six formulations of a trastuzumab biosimilar were screened by combining 8 types of excipient modifiers with 4 types of buffers across a pH range of 4.5 to 7.5. Key stability risks, including high molecular weight (HMW) aggregation and fragmentation, were thoroughly assessed along with viscosity at high concentrations. Additionally, several biophysical parameters were evaluated for their ability to predict stability or viscosity outcomes. Multiple linear regression was applied to fit the data and identify key factors. Results The optimal pH range for the trastuzumab biosimilar was found to be 5.0 to 6.5, based on opposing pH dependencies for stability and viscosity. Buffer type had a minor effect on viscosity and fragmentation but played a significant role in influencing HMW aggregates, with Na-acetate and histidine-HCl being the best candidates. The impact of excipient modifiers on viscosity, HMW, and fragmentation depended on both pH and buffer type, showing strong interactions among factors. Arginine-HCl and lysine-HCl effectively lowered viscosity of the trastuzumab biosimilar at pH levels above 6.0, while glycine formulations were more effective at reducing viscosity below pH 6.0. Histidine-HCl, arginine-HCl, and lysine-HCl lowered the risk of HMW aggregation, whereas formulations containing Na-phosphate or NaCl showed higher HMW aggregation. Formulations with arginine-HCl, lysine-HCl, and NaCl demonstrated a rapid increase in fragmentation at pH levels below 5.0, while Na-aspartate formulations showed increased fragmentation at pH levels above 6.5. Conclusion Hence, it is important to optimize the levels of each chosen excipient in the formulation study to balance their benefits against potential incompatibilities. This study serves as a foundation for identifying high-concentration antibody formulations using a high-throughput approach, where minimal materials are required, and optimized formulation design spaces can be quickly identified.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.