Abstract

To assess the learning curve for performing reliable liver stiffness measurements using a new hybrid machine composed of transient elastography (TE) interfaced with an ultrasound device for radiographers and radiologists with different levels of expertise in ultrasound imaging. Ten novice operators who had never performed TE measurements were prospectively evaluated from April to October 2018: senior radiologists, young radiologists, fellows, radiographers, and residents, with different levels of experience in abdominal ultrasound imaging. All operators had a short theoretical training followed by a training session under supervision in three patients. Then, each operator had to perform TE in 50 consecutive patients with chronic liver disease, using beforehand ultrasound examination to select measurement area in the right liver lobe, and if needed, the XL probe. Percentages of failures and reliable measurements were compared. The rates of failures of measurements, poorly reliable, reliable, and very reliable results, were of 4.2% (21/500), 2.4% (12/500), 47.6% (238/500), and 45.8% (229/500), respectively. The rates of reliable plus very reliable results were excellent, ranging from 91 to 96% among all the subgroups. The rates of very reliable, reliable, and unreliable results did not differ between operator subgroups and especially between junior radiologists, senior radiologists, and radiographers. No breaking point was observed in the interquartile range/median values over time. TE interfaced with ultrasound in this hybrid machine presents no learning curve effect. After a short initial training session, a novice observer is able to perform high rates of reliable and very reliable TE measurements. • When performing liver stiffness measurements using a new hybrid machine composed of transient elastography interfaced with ultrasound, the rate of failures of measurements is very low, below 5%. • After a short training session and using ultrasound planning, a novice operator, whatever its expertise in ultrasound imaging, is capable of performing high rates of reliable and very reliable measurements. • No learning curve is needed for performing reliable liver stiffness measurements using this new hybrid machine.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.