Abstract

A new method to detect leakage in a water-filled plastic pipe is proposed. In this method, a leakage signal-signature in time domain is first captured by monitoring the Short Time Fourier Transforms (STFT) of AE (Acoustic Emission) signals over a relatively long time-interval. The captured signal is then used to find a mother wavelet (tuned wavelet) for the best signal localization in time and frequency domains. The technique for AE signal detection using tuned wavelet is then described. Practical application of the method proposed herein is then presented using a water-filled plastic pipe as a case study. Signals generated from this experimental setup are collected to identify leakage signal-signatures from other interfering signals (background, pipe natural frequency, splash and environmental noise). The results of the experiment prove that using tuned wavelet, AE events can be detected and identified precisely in time. In addition, sources of signals due to leakage and their respective energy levels can also be recognized.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.