Abstract

The development of low power consumption sensing devices for detecting trace toxic gases is imperative for a wide variety of applications. Recently, hybrid organic–inorganic lead perovskite-based sensors have been fabricated to demonstrate their potential for gas sensing application. However, the poor repeatability and toxicity of lead halide perovskites severely restrict their further practical applications. Here, the lead-free all-inorganic cesium copper iodide (CsCu <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> I <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> ) perovskite nanostructured networks are deposited onto interdigital electrodes patterned substrate as the gas sensitive layer via simply spin coating the precursors. The sensor exhibites excellent room temperature NO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> sensing properties, including ultra-low limit of detection, excellent repeatability, and good selectivity. Dynamic testing displays the good cycling repeatability of the sensor for ppb level NO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> . The ultra-sensitive NO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> sensing behavior of the CsCu <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> I <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> nanostructure networks are mainly attributed to the unique nanoneedle clusters network structure and large amount of cation vacancies on the perovskite surface. In conclusion, the high sensitivity and environmentally friendly CsCu <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> I <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> sensor shows great potential for trace indoor pollutants detection and breathe analysis for disease diagnosis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.