Abstract
Lead attenuation characteristic curves are often consulted in premises radiation shielding assessments employing the non-destructive testing (NDT) method. This study developed lead attenuation characteristics mathematical models for the radionuclide Co-57. These models take into account the statistical variation of the attenuation characteristics. The results are a set of equations that a NDT assessor can use to predict the range of transmission factors for the NDT measurement or, using the inverse functions, to gauge the lead equivalence (with the associated uncertainty) of a radiation barrier. This study showed that the combined effect of types of statistical variations can form an uncertainty region on the transmission characteristics such that the relative uncertainty decreases for values of lead mass per unit area up to approximately 20 kg/m2 and 15 kg/m2 for the Ludlum 18 and Ludlum 2241-2 survey meters respectively but thereafter increases.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Australasian Physical & Engineering Sciences in Medicine
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.