Abstract

Aim: HCP002, a phosphate-modified derivative of voriconazole, can improve solubility without using the nephrotoxic solubilizer, sulfobutylether-β-cyclodextrin. To study pharmacokinetics in humans, LC-MS/MS methods to quantify HCP002 in human plasma and urine were developed and validated. Method: After protein precipitation by acetonitrile containing voriconazole-d3, HCP002 was separated on a ZORBAX SB-Aq column, and LCMS/MS analysis was performed in multi-response monitoring mode. Results: The analytical run time was 3min. Linearity was observed over the ranges of 0.100-40.0 and 0.400-200μg/ml in plasma and urine, respectively. Precision and accuracy were within acceptable limits. Sample stability was confirmed. Conclusion: Rapidand reproducible methods quantified HCP002 in urine, and plasma samples were established.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call