We propose a method for estimating the convective-heat-transfer coefficient (CHTC) distribution on building walls by using the water-evaporation method involving filter paper and three-dimensional laser scanning, and demonstrates consistency with the gravimetric evaporation method. The theory and method are established based on the convective heat- and mass-transfer analogy and a near-infrared laser-scanning system. The equations to remotely estimate the CHTC distribution are obtained empirically, and the proposed method is applied to the walls of a penthouse during winter. The spatial distribution of the surface reflection intensity that determines the evaporation rate is successfully retrieved with 0.2–0.3% accuracy from a measurement distance of 5 m. The comparison of evaporation rates with a gravimetric measurement does not show a statistically significant bias. The results show that the crucial factors for the precision of the CHTC estimation are errors in the laser-scanning system and their amplification when dividing the evaporation rate by the vapour pressure deficit to obtain the convective-mass-transfer coefficient. The estimated CHTC distributions on the target walls have approximately ≤ 2–3 W m−2 K−1 errors in the 95% confidence interval after applying spatial and/or temporal averaging. Although the error in the convective-heat-transfer coefficient is larger in winter during minimal vapour pressure deficits, it is generally well explained in the range of the random error in laser scanning. The correlation between the spatially-averaged convective-heat-transfer coefficient and near-wall wind speed is comparable to existing methods (R = 0.71–0.79), and the regression relation agrees with that obtained in previous studies performed in similar conditions.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call