An experiment was carried out using a scale model of a tall building, with the goal of investigating the role of individual buildings in the dispersion of air pollution. Pollutant dispersion around an isolated building with a height-to-length aspect ratio of 1.4 is investigated using simultaneous particle image velocimetry and planar laser induced fluorescence. Dye is released from a ground-level point source five building heights upstream of the tall building. It was found that in this case the scalar plume was dispersed laterally strongly by the building, but only slightly vertically. It is hypothesized that this is due to 94% of the plume impinging below the stagnation point on the front of the building and being drawn into the horseshoe vortex. We expect this fraction would be lower in a case in which the building is in an array of smaller buildings, and that this would lead to more vertical dispersion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.