Abstract
The results of an experimental investigation on the large signal behavior of a kilowatt power level helix type traveling-wave amplifier tube are presented. Operation with and without attenuators was investigated using a movable electromagnetic probe to measure power level along the tube. Quite different effects of drive power and beam voltage on the saturation level were found for operation with and without attenuators. The maximum power level is lower for attenuator operation. Also, power levels do not continue to increase with increasing beam voltage and drive power. In contrast, attenuator-less operation produces the highest efficiency, and the power levels continue to rise with increasing beam voltage and drive power. Conversion efficiencies as high as 25 per cent are obtained with an attenuator and as high as 40 per cent without an attenuator. Efficiency calculations based on small-signal theory can be made to agree reasonably well with the experimental attenuator-less operation efficiencies by assuming an appropriate ratio of the ac component of beam current to the dc component of beam current, i/I 0 .
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.