Abstract

Compact X-rays detectors made of 1/2” or 1” :LaBr3:Ce crystals of cubic shape with SiPM array readout have been developed for the FAMU experiment at RIKEN-RAL. The aim is a precise measurement of the proton Zemach radius with incoming muons. Additional applications may be found in medical physics, such as PET, homeland security and gamma-ray astronomy. Due to the high photon yield of LaBr3:Ce it was possible to use a simple readout scheme based on CAEN V1730 digitizers. Detectors, using Hamamatsu S13361 or S14161 arrays, have good FWHM energy resolutions up to 3% (8%) at the Cs137 (Co57) peak, comparing well with the best results obtained with a photomultiplier’s readout. Detailed studies were performed to correct online the drift with temperature of SiPM gain and to reduce the risetime/falltime of detectors’ signals, that increased going from 1/2” to 1” detectors, due to the larger capacity of the used SiPM arrays.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.