Abstract
Stepped spillway and stilling basin are one of the most important energy dissipation structures. Eventhough, most of energy dissipated by these structures, but in skimming flow, the upstream flow motion is nonaerated and the residual energy capable to destroyed structures during floods. In this study, effect of stilling basin slope on bed scour, downstream of Javeh dam was investigating. Experiments performed in hydraulic structures laboratory of the University of Kerman with six different discharges (5, 7, 13, 17, 25 and 30 l/s.m) and five various stilling basin slope (0.02, 0.01, 0, −0.01 and − 0.02). The parameters such as maximum scour depth (ds), flow velocity (in three point), water depth on upstream and downstream of stepped spillway and stilling basin, the distance of the maximum scour depth to sill (Ls) and the gheometery of scour hole measured. Result shown that when stilling basin slopes was 0.02, the average of maximum relative scour depth, 47% Increased and in −0.02, 52.2% Decreased. In addition, the distance of maximum scour depth until stilling basin increased by increasing and decreased by decreasing the stilling basin slope.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.