Abstract

A kirigami-based strategy was investigated for strain transduction, using serpentine gold traces embedded in thin-film Parylene C. Multiple kirigami slit designs were evaluated via COMSOL simulation and mechanical force testing; sensors having tightly packed slits stretched up to 17.5 mm (350% strain) before mechanical failure and 9 mm (180% strain) before electrical failure. Strain transduction was achieved by monitoring DC resistance changes during stretching. DC resistance linearly increased with strain, with sensitivities up to 0.16 $\Omega$ /mm (gauge factor = 0.007) and minimal hysteresis. High-frequency trace impedance and inter-trace capacitance were also investigated during strain cycling. Capacitance increased with strain and high-frequency impedance show a nonlinear strain relationship. The biocompatible construction and extremely low profiles (20 $\mu \text{m}$ thick) of these sensors are attractive for minimally invasive in vivo strain sensing applications. [2018-0130]

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.