Abstract

The kinetics of the clogging of filters by submicron solid aerosol particles in the diffusion mode of deposition is studied, and a method is developed for optimizing the parameters of a prefilter in a two-stage system of fine air cleaning that consists of a prefilter and a final filter. The relation of the maximum allowable pressure drop to the optimum radius of the fibers, the optimum thickness of the prefilter, and the volume of the particles captured by the system is derived. It is shown that at a fixed radius of the fibers, the dependence of the final pressure drop and the dust holding capacity on the radius of the particles has a maximum that approximately corresponds to the radius of most penetrating particles.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.