Abstract

The basic results of computational and experimental studies of passive systems of emergency heat removal in application to ship and portable reactor facilities are presented. The methodological correlations for calculations of heat removal systems with condensation of steam in a bundle of inclined tubes under mixed convection conditions in the presence of non-condensing gases and the true volume steam content in a vertical large-diameter tube are developed. The optimization of the cooling loops of systems performing emergency heat removal at pressure close to atmospheric and suggestions for improving a passive system of emergency heat removal from a reactor are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.