Abstract

Semi-recumbent cycling performed from a wheelchair is a popular rehabilitation exercise following spinal cord injury (SCI) and is often paired with functional electrical stimulation. However, biomechanical assessment of this cycling modality is lacking, even in unimpaired populations, hindering the development of personalised and safe rehabilitation programs for those with SCI. This study developed a computational pipeline to determine lower limb kinematics, kinetics, and joint contact forces (JCF) in 11 unimpaired participants during voluntary semi-recumbent cycling using a rehabilitation ergometer. Two cadences (40 and 60 revolutions per minute) and three crank powers (15 W, 30 W, and 45 W) were assessed. A rigid body model of a rehabilitation ergometer was combined with a calibrated electromyogram-informed neuromusculoskeletal model to determine JCF at the hip, knee, and ankle. Joint excursions remained consistent across all cadence and powers, but joint moments and JCF differed between 40 and 60 revolutions per minute, with peak JCF force significantly greater at 40 compared to 60 revolutions per minute for all crank powers. Poor correlations were found between mean crank power and peak JCF across all joints. This study provides foundation data and computational methods to enable further evaluation and optimisation of semi-recumbent cycling for application in rehabilitation after SCI and other neurological disorders.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call