Abstract
An isocratic reversed-phase high-performance liquid chromatographic (HPLC) method using an Ultrasphere IP column has been developed for the determination of testosterone and its metabolites after incubation of 4- 14C-labelled or unlabelled testosterone with rat liver microsomes. Compounds were eluted with methanol-water-tetrahydrofuran (35:55:10, v/v, pH 4.0) and detected by ultraviolet (UV) absorption at 245 nm. UV or on-line radioactivity detection can be used although, due to differences in detector cell volumes, peak resolution is slightly better with UV detection. Selectivity was validated by collecting HPLC peaks and verifying their identity by gas chromatography-mass spectrometry after derivatization by N,O-bis(trimethylsily)trifluoroacetamide-trimethylchlorosilane. A three-day validation was performed to determine the linearity, repeatability, reproducibility and accuracy of the method, using corticosterone as internal standard. The method is applicable to the measurement of cytochrome P-450 isoenzyme activities in rat liver.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Chromatography B: Biomedical Sciences and Applications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.