Abstract

Background The ventricular repolarization (VR) response to short-lasting coronary occlusion has been characterized by 3-dimensional vectorcardiography (VCG) in humans; the T vector loop becomes distorted and more circular. The purpose of this study was to relate these changes to the size of the myocardium at risk (MAR) and its location. Methods Continuous VCG was applied during transient coronary occlusion in 35 elective angioplasty patients, and the size of the MAR was estimated by single-photon emission computed tomography. Three VR aspects were assessed at baseline vs maximum ischemia: the ST segment, the T vector angles, and the T vector loop morphology. Results The T loop morphology changes were significantly associated with MAR size, but also dependent of its location. In contrast, the early phase of VR reflected by the ST segment responded to acute ischemia in relation to the MAR size independent of location. Conclusion The VR changes were related both to the size and the location of the MAR and most pronounced during occlusion of the left anterior descending artery.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.