President Critical-Care; Baxter Healthcare Corporation; Santa Ana, CaliforniaIn Reply:- We agree with the authors' comments that “… protective sheaths are a known source for damage to the (catheter) balloon …” and that “their potential for damaging the pulmonary artery catheter coating must be recognized.”Baxter salutes the authors' efforts to raise awareness of the potential for certain introducer systems with contamination shields to cause damage to a pulmonary artery catheter's thermal filament shield, balloon, or both.Product literature for the Arrow Twist Lock Cath-Gard Catheter Contamination Shield Model ST-09875 (80 cm) includes precautionary statements relating to possible balloon flotation catheters. The contamination shield has a firm, plastic feed tube running through the center of the shield, which supplies a path for the catheter to be passed through. Given the possibility that contact between the catheter and edges of the feed tube may disrupt the thermal filament sheath on the catheter, we agree with the authors' suggestion to visually inspect the integrity of the catheter after it has been passed through a contamination shield, before insertion into the introducer.We also wish to address the authors' comments that the thermal filament on a continuous cardiac output catheter is “an area less flexible and slightly thicker than the remaining part of the pulmonary artery catheter … .” With respect to Baxter's Swan-Ganz Continuous Cardiac Output/Oximetry/Venous Infusion Port (CCO/SvO2/VIP) Thermodilution Catheters, the diameter at the thermal filament area is equal to or slightly smaller than the rest of the catheter and shows comparable flexibility characteristics at all temperatures.Based on our experience and as indicated in the relevant portions of the product literature provided by Baxter and Arrow, certain steps should be taken to minimize the possibility of damage to pulmonary artery catheters that are inserted through contamination shields:1. Prepare the catheter for insertion per the manufacturer's instructions.2. Make sure both valves on the Arrow contamination shield at the proximal and distal hubs are in the widest open position.3. Wet the catheter balloon and thermal filament sheath with flush solution to facilitate passage through the valves of the contamination shield.4. Insert the catheter into the compressed shield and place the shield over the catheter so the distal flanged hub is beyond the 50-cm mark on the catheter.5. Inspect the catheter balloon and thermal filament sheath (if a continuous cardiac output catheter) for damage.6. If the catheter is not damaged, insert the catheter at least beyond the thermal filament into the introducer before moving the contamination shield, and then complete the catheter insertion following the manufacturer's instructions.7. Position, expand, attach, lock, and maintain the sheath as outlined in the manufacturer's instructions.Alan R. OlhoeftPresident Critical-Care; Baxter Healthcare Corporation; Santa Ana, California(Accepted for publication April 24, 1998.)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.