Abstract

BackgroundThe lengths of right renal veins are shorter when compared to their left counterparts. Since the implantation of kidneys with short renal veins is considered more challenging, many surgeons prefer left kidneys for transplantation. Therefore, our hypothesis is that the implantation of right kidneys from living and deceased donors is associated with more technical graft failures as compared to left kidneys.MethodsTwo consecutive cohorts of adult renal allograft recipients of living (n = 4.372) and deceased (n = 5.346) donor kidneys between January 1, 2000 and January 1, 2013 were analyzed. Data were obtained from the prospectively maintained electronic database of the Dutch Organ Transplant Registry. Technical graft failure was defined as failure of the renal allograft within 10 days after renal transplantation without signs of acute rejection.ResultsIn the living donor kidney transplantation cohort, the implantation of right donor kidneys was associated with a higher incidence of technical graft failure (multivariate analysis p = 0.03). For recipients of deceased donor kidneys, the implantation of right kidneys was not significantly associated with technique-related graft failure (multivariate analysis p = 0.16).ConclusionsOur data show that the implantation of right kidneys from living donors is associated with a higher incidence of technique-related graft failure as compared to left kidneys.

Highlights

  • MethodsTwo consecutive cohorts of adult renal allograft recipients of living (n = 4.372) and deceased (n = 5.346) donor kidneys between January 1, 2000 and January 1, 2013 were analyzed

  • The general opinion is that the implantation of renal allografts with shorter renal veins is technically more challenging

  • Our hypothesis is that the implantation of right kidneys from living and deceased donors is associated with more technical graft failures as compared to left kidneys

Read more

Summary

Methods

Two consecutive cohorts of adult renal allograft recipients of living (n = 4.372) and deceased (n = 5.346) donor kidneys between January 1, 2000 and January 1, 2013 were analyzed. Data were obtained from the prospectively maintained electronic database of the Dutch Organ Transplant Registry. Technical graft failure was defined as failure of the renal allograft within 10 days after renal transplantation without signs of acute rejection

Results
Introduction
Materials and methods
Results and discussion
Compliance with ethical standards

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.