Abstract

An ion sensitive probe (ISP) has been installed in the divertor simulation module of the largest tandem mirror plasma device GAMMA 10/PDX in order to evaluate the property of the high temperature end loss plasmas. The ISP has the capability to evaluate ion temperature (Ti), electron temperature (Te), electron density and plasma space potential, simultaneously. We have tested the ISP measurement for several discharge and neutral gas pressure conditions. Tievaluated by using an ion collector of the ISP shows ∼6 eV which corresponds to the perpendicular component of Ti in principle. Te evaluated by the current-voltage characteristics of an electron guard electrode of the ISP shows ∼4 eV which is lower than Te obtained by Langmuir probes upstream and downstream of the ISP. These results indicate the existence of anisotropic ion and electron temperatures in the D-module.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.