In this article, we present ion energy distributions (IEDs) at a rf-biased surface as a function of driving frequency and ion mass. The experiments were carried out in high-density inductively coupled rare-gas (Ne,Ar,Xe) plasmas. Our quadrupole mass and cylindrical-mirror energy analyzer sampled ions incident on a rf-biased pinhole located in the center of the wafer chuck. The electron density, electron temperature, and plasma and chuck potential oscillations were measured, and they provided inputs to numerical models used to predict IEDs, which were shown to closely match our experimental results under certain conditions. For a given driving frequency, heavier ions showed narrower IEDs and, for a given ion mass, the IED became narrower and shifted to a higher mean energy with increased driving frequency, in agreement with calculations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.