Abstract

AbstractThe study analyzed surface treatment's impact on mechanical properties of Fe-based amorphous coatings. Specimens underwent six-hour treatments at 670 and 770 °C using vacuum heat. Results revealed distinct mechanical features in the coating: Vickers hardness reached 755, scanning electron microscope images displayed glassy phases, showcasing good wear resistance and compressive residual stresses at around −55 MPa. A remarkable 122% increase in compressive residual stress was noted through combined vacuum heat treatment and sandblasting. Volume wear decreased from the initial 18 to 14 mm3 after treatment at 670 °C followed by sandblasting, indicating a 30% enhancement in wear resistance. Yet, using vacuum heat treatment at 770 °C negatively impacted the coating's properties.