Abstract

Nomex insulation paper has been widely used in mining dry type transformer insulation because of its excellent performance. However, the injection of space charge can affect the electrical properties of the Nomex paper and accelerate the ageing process of the insulation system, which causes the insulation system failure or even breakdown. Therefore, it is of great practical value to study the space charge characteristics of Nomex insulation paper in different hygrothermal ageing conditions. The accelerated hygrothermal ageing tests of Nomex insulation specimens with different initial moisture contents were conducted. The space charge distribution of specimens impregnated by varnish were measured by the pulsed electro-acoustic method at different ageing stages. Simultaneously, the space charge characteristics during polarising and depolarising phases were deeply analysed. Experimental results show that negative charges accumulate between the varnish-paper interface in specimens near the anode. The number of negative charges gradually decreases with the increase of ageing degree. Under the influence of humidity, Nomex paper can be hydrolysed, which increases the trap density and trap level. Finally, a large amount of positive and negative charges in aged specimens would result in the distortion of the local electric field, which could decrease the breakdown strength of Nomex insulation specimens and be a threat to transformer insulation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call