Abstract
For the purpose of investigating fusion-produced neutron effects on semiconductor x-ray detectors, detection characteristics of x-ray tomography detectors used before and after deuterium–tritium (DT) and/or DD fusion-plasma experiments in the Joint European Torus (JET) tokamak are studied using synchrotron radiation from a 2.5 GeV positron storage ring at the Photon Factory. Degradations in the responses after neutron exposure into the detectors are found to have functional dependence on x-ray energy. Changes in the depletion thicknesses of the detectors are investigated by means of impedance analyses. The Fusion Neutronics Source (FNS) facility of the Japan Atomic Energy Research Institute is also employed for well calibrated DT fusion-produced neutron irradiation onto these semiconductor x-ray detectors. Recovery of the response degradation is found due to a method for supplying the operational bias to the degraded detector. Our theory is applied to interpret these detector characteristics under the irradiation of DT fusion-produced neutrons in the JET tokamak and the FNS facility.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.