Abstract

The parameters effecting the efficiency of thorium extraction on silica gel coated with Tri-octylphosphine oxide(TOPO) such as; HNO 3 concentration, thorium concentration, TOPO concentration, flow rate and nature of diluent were studied and optimum conditions were determined. Various elution reagents were tried to elute thorium from the column. High recovery was obtained with 0.5 M H 2SO 4, 0.5 M HCl solutions. Extraction data have been used to separation thorium from iron(III) and Ce(IV). The solution that contains Fe(III), Ce(IV) and Th(IV) in nitric media was passed through the TOPO/silica gel column, whilst Th(IV) and Ce(IV) were extracted by TOPO, Fe(III) was not. Firstly Th(IV) was eluted with H 2SO 4 then Ce(IV) was eluted with HCl. As a result, optimum conditions are here reported for the separation of thorium from cerium(IV).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.