The process of development of the third heat transfer crisis for vertical orientation of the heating surface was studied experimentally. Experiments were carried out with acetone under the conditions of saturation for the pressures in the working volume from 20 to 28 kPa. In all experiments, the third heat transfer crisis was preceded by propagation of evaporation front along the heating surface. The threshold values of heat flux densities, above which a stable vapor film is formed on the whole heating surface, are lower for vertical orientation of this heating surface than for the horizontal one. Data on the threshold heat flux densities and overheating before boiling-up were obtained. Above these values, formation of evaporation fronts was observed. The range of operation parameters corresponding to formation of the sites of unstable film boiling on the heating surface after boiling-up was determined.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.