Abstract

A large area inductively coupled plasma source with an internal linear-type antenna was operated in dual frequency mode (2 MHz/13.56 MHz), and the electrical/plasma characteristics of the ICP source were examined as a function of the relative rf power ratio. When the source was operated in single frequency mode (13.56 MHz only), approximately 8.5% plasma uniformity was observed at 5 kW of 13.56 MHz rf power for the substrate size of 880 mm × 660 mm. The plasma uniformity improved with increasing rf power. However, a further improvement in plasma uniformity to approximately 6.3% could be obtained using the dual frequency mode by applying 0.9 kW of 2 MHz rf power in addition to 5 kW of 13.56 MHz. For 15 mTorr Ar, the plasma density at a dual frequency rf power of 0.9 kW 2 MHz/5 kW 13.56 MHz was 1.6 × 10 11/cm 3 and the electron temperature was approximately 3 eV. The addition and increase in 2 MHz rf power to the 13.56 MHz power increased the plasma density without increasing the electron temperature.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.