Abstract
The paper describes experimental and computational fluid dynamics analyses of the non-uniform static pressure distortion caused by the discharge volute in a high pressure, centrifugal compressor. The experiments described in this paper were done using a heavily instrumented gas re-injection compressor operating at over 6000 psia discharge. Instrumentation was installed to measure static, total, and dynamic pressure as well as impeller strain and mechanical vibrations. A brief description of the compressor and instrumentation are provided. Concurrent with the experimental work, CFD runs were completed to study the reasons for the pressure non-uniformity. The CFD pressure profile trends agreed well with the experimental results and provided analytical corroboration for the conclusions drawn from the test data. Conclusions are drawn regarding: a) the response of the non-uniformity to changing flow rates; b) the extent to which the non-uniformity can be detected upstream of the impeller; and c) the mechanical influences of the non-uniformity on the impellers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.