Abstract

Slug catchers offer effectively multiphase flow management in the field of oil and gas industry. critical equipment required for isolates and confines liquid, gases, and solid particles in slugs under environmental conditions that observed to incoming production stream. This work examines the case study that undergoes corrosion failure in vessels of slug catcher, concentrating on (H2S) damage, hardness, and microscopic corrosion in different locations. The methodology of this study involved visual inspections, hardness, and microscopic testing in order to evaluate the level of nature corrosion. The results refer that while the failure of corrosion pits present, there were not cracks, microcracks, stress corrosion cracking (SCC), or Hydrogen Induced Cracking (HIC) recognized in the structural of vessel. The structures of ferrite and pearlite of the HIC were presented in main components, and there are no cracks or microcracks detected.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.