Abstract

Results of our experimental investigation on the ozone zero phenomenon suggested us the importance of the electrode surface condition. This means that the main cause of the phenomenon, that is, temporal decrease of ozone concentration at the outlet of DBD type ozone generator and the recovery characteristics from the phenomenon are considered as the surface reaction process, which are influenced strongly by the surface condition. The surface condition is never constant during the ozone generation and varies gradually or remarkably with time depending on the experimental conditions. Therefore we have been continued to make clear the cause of the phenomenon, for example, the reproducibility of the phenomenon, using new electrodes and together with the surface analysis technique etc. In this paper, we describe on the above results and discussion.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call