Abstract

Positron lifetime, annihilation line shape, and electron microscopic measurements have been carried out on neutron irradiated pressure vessel steel (HSST Plate 03) meeting ASTM A533-B (Unified Numbering System [UNS] K12539). The positron annihilation parameters for specimens irradiated at 423 K to a dose of 1.5 × 1018 n/cm2 are found to decrease sharply during the post-irradiation annealing interval, 473 to 623 K. This correlates well with the stage seen in the recovery of Vickers hardness. On the basis of known evidence for carbon migration in α-iron and the interpretation of present results, enhancement and recovery of radiation hardening have been qualitatively understood in terms of formation and dissolution of carbon decorated vacancy complexes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.