Abstract

The aim of the current study is to investigate the ability of micro-ultrasound (microUS) to identify microvasculature in CTOs in vivo. Results are compared with MRI studies. CTOs were developed in nine porcine superficial femoral arteries (SFA) by percutaneous insertion of a dissolvable polymer plug. This model is characterized by acute thrombosis that later organizes into a fibrotic CTO containing abundant microchannels. 3D microUS images with Power Doppler (PD) overlays from the arteries were acquired at two timepoints: one and eight weeks after placement ofthe polymerplug. Phase contrast MRI and contrast enhanced MRI was also performed. Imaging was performed transcutaneously. Microvessels were identified in vivo in six of eight CTOs using microUS, and in three of seven CTO vessels with MRI, compared with five of seven seen histologically. PW Doppler profiles showed pulsatile blood velocities of approximately 2 cm/s. Intraluminal microvessels within CTOs can be consistently identified by 3D microUS. This technique appears to be more sensitive than MRI. MicroUS may play a role in guiding CTO interventions.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call