Abstract

Most previous split anode calorimetry research has applied high weld currents which exhibit pseudo Gaussian distributions of arc current and power density. In this paper we investigate low current arcs and show that both the current and power distributions have minima in the centre – varying significantly from the expected Gaussian profile. This was postulated due to the formation of the arc with the copper anode and the tungsten cathode. Furthermore, a number of parameters were varied including the step size between measurements, anode thickness and anode surface condition as well as cathode type and tip geometry. The step size between measurements significantly influenced the distribution profile and the anode thickness needed to be above 7 mm to obtain consistent results.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.