Abstract

This study investigates thermodynamic parameters and exergetic efficiency of the Salihli geothermal district heating system (SGDHS) in Manisa, Turkey for 2005/2006 heating season. The thermodynamic parameters considered are as follows: (i) fuel depletion rate, (ii) relative irreversibility, (iii) productivity lack, and (iv) exergetic factor. These parameters are determined for the system to assess and compare their individual performances. While the highest relative irreversibilities occur in the heat exchangers with the values of 44% for the SGDHS, exergetic efficiency of the system is found to be 60.3%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.