Abstract

Current leads supply electrical energy from a room-temperature power supply to a superconducting application, representing thus a major thermal load. State-of-the-art cooling solutions use either open (vapor cooled) or multi-stage closed cycle systems. The multi-stage concept can be integrated in one cryogenic mixed refrigerant cycle (CMRC), where a wide-boiling fluid mixture absorbs the heat load continuously along the current lead. In this paper, we study the combination of CMRC cooling with Peltier elements at the warm end of DC current leads. The Peltier cooling may cause a temperature drop on the order of 80 K. This allows an optimization of the CMRC mixture composition towards lower temperatures, avoiding the use of high-boilers that risk to freeze out at low temperatures. Our studies suggest that Peltier and CMRC cooling can reduce the thermal load at the cold end by 30 to 45% compared to conventional conduction-cooled current leads.

Highlights

  • Grohmann CEC-ICM 2019 C1Or2B-07 – Superconducting RF Systems, Power Cables, and Leads I

  • KIT – The Research University in the Helmholtz Association www.kit.edu

  • Efficient transport of electrical current from room-temperature to a superconducting application at the cryogenic temperature

Read more

Summary

Introduction

Grohmann CEC-ICM 2019 C1Or2B-07 – Superconducting RF Systems, Power Cables, and Leads I

Objectives
Results
Conclusion