Abstract

In this study, we investigate the torque response of a control system that is based on the direct torque control (DTC) principle for an interior permanent magnet synchronous motor (IPMSM). We also propose a gain-scheduling method for improving the torque response. Reference flux vector calculation (RFVC) DTC is used in this study. In RFVC DTC, a PI controller is used for torque control; this is in contrast to the use of the hysteresis comparator and switching table in basic DTC. In this paper, we present the relationship between the torque response and the gain of the PI controller. This relationship is derived by using the transfer function of the torque control loop. In this study, we also examine the difference between the torque responses of two motors that have different machine parameters. The proposed method can be used to realize a torque response that is independent of the operating torque. The simulation results and experimental results presented in this paper show the validity of the derived relationship as well as the effectiveness of the proposed method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.