Abstract
Interscan reproducibility of coronary artery calcium (CAC) scoring can be improved by using a smaller slice thickness but at the cost of higher image noise. This study aimed to investigate the feasibility of using densely connected convolutional network (DenseNet) to reduce the image noise in CAC scans reconstructed with slice thickness < 3 mm for improving coronary calcification detection in CT. Phantom data acquired with QRM and CIRS phantoms were used for model training and testing, where the DenseNet model adopted in this work was a convolutional neural network (CNN) designed for super resolution recovery. After phantom study, the proposed method was evaluated in terms of its ability to improve calcification detection using patient data. The CNN input images (IMGinput) were CAC scans reconstructed with 0.5-, 1.0- and 1.5-mm slice thickness, while CNN label images were CAC scans reconstructed with 3-mm slice thickness (IMG3mm). Region of interest (ROI) analysis was carried out on IMG3mm, IMGinput and CNN output images (IMGoutput). Two-sample t test was used to compare the difference in Hounsfield Unit (HU) values within ROI between IMG3mm and IMGoutput. For the calcifications in QRM phantoms, no statistically significant difference was found when comparing the HU values of 400- and 800-HA calcifications identified on IMG3mm to those on IMGoutput with slice thickness of 0.5, 1.0 or 1.5 mm. On the other hand, statistically significant difference was found when comparing the HU values of 200-HA calcifications identified on IMG3mm to those on IMGoutput with a slice thickness of 0.5 and 1.0 mm. Meanwhile, no statistically significant difference was found when comparing the HU values of 200-HA calcifications identified on IMG3mm to those on IMGoutput with a slice thickness of 1.5 mm. As for the rod inserts in CIRS phantoms simulating 9 different tissue types in human body, there was no statistically significant difference between IMG3mm and IMGoutput with slice thickness of 1.5 mm, and all the p values were larger than 0.10. With regards to patient study, more calcification pixels were detected on IMGoutput with a slice thickness of 1.5 mm than on IMG3mm, so calcifications were more clear on the denoised images. According to our results, the CNN-based denoising method could reduce statistical noise in IMGinput with a slice thickness of 1.5 mm without causing significant texture change or variation in HU values. The proposed method could improve cardiovascular risk prediction by detecting small and soft calcifications that are barely identified on 3-mm slice images used in conventional CAC scans.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.