Abstract

ObjectiveTo evaluate the added benefit of diffusion-weighted imaging (DWI) over clinical parameters in predicting kidney allograft function decline.MethodsData from 97 patients with DWI of the kidney allograft were retrospectively analyzed. The DWI signals were analyzed with both the mono-exponential and bi-exponential models, yielding total apparent diffusion coefficient (ADCT), true diffusion (D), pseudo-diffusion (D*), and perfusion fraction (fp). Three predictive models were constructed: Model 1 with clinical parameters, Model 2 with DWI parameters, and Model 3 with both clinical and DWI parameters. The predictive capability of each model was compared by calculating the area under the receiver-operating characteristic curve (AUROC).ResultsForty-five patients experienced kidney allograft function decline during a median follow-up of 98 months. The AUROC for Model 1 gradually decreased with follow-up time > 40 months, whereas Model 2 and Model 3 maintained relatively stable AUROCs. The AUROCs of Model 1 and Model 2 were not statistically significant. Multivariable analysis showed that the Model 3 included cortical D (HR = 3.93, p = 0.001) and cortical fp (HR = 2.85, p = 0.006), in addition to baseline estimated glomerular filtration rate (eGFR) and proteinuria. The AUROCs for Model 3 were significantly higher than those for Model 1 at 60-month (0.91 vs 0.86, p = 0.02) and 84-month (0.90 vs 0.83, p = 0.007) follow-up.ConclusionsDWI parameters were comparable to clinical parameters in predicting kidney allograft function decline. Integrating cortical D and fp into the clinical model with baseline eGFR and proteinuria may add prognostic value for long-term allograft function decline.Critical relevance statementOur findings suggested that cortical D and fp derived from IVIM-DWI increased the performance to predict long-term kidney allograft function decline. This preliminary study provided basis for the utility of multi-b DWI for managing patients with a kidney transplant.Key points• Both clinical and multi-b DWI parameters could predict kidney allograft function decline.• The ability to predict kidney allograft function decline was similar between DWI and clinical parameters.• Cortical D and fp derived from IVIM-DWI increased the performance to predict long-term kidney allograft function decline.Graphical

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call