Abstract
BackgroundResidual mitral regurgitation (MR) is thought to be an important predictor of long-term survival following transcatheter edge-to-edge repair (TEER). Intraprocedural MR assessment using transesophageal echocardiography could be limited by image quality, hemodynamics, and patient sedation. The MitraScore is a validated multimodal approach for intraprocedural MR assessment during TEER. ObjectivesThis study aimed to assess the impact of residual MR using the MitraScore on 1-year mortality. MethodsPatients undergoing mitral TEER were eligible for inclusion in the prospective, multicenter MITRA-PRO registry (A Prospective Registry Study on 1-Year Mortality and the Prognostic Significance of MitraScore After MitraClip Implantation in Patients With Mitral Regurgitation). Patients with a MitraScore ≤3 were defined as patients with mild residual MR after mitral TEER, whereas a MitraScore ≥4 was considered as relevant residual MR. Mortality, rehospitalization, and major adverse events were assessed 1 year after TEER. ResultsA MitraScore ≤3 was found in 1,059 patients (71.0%), whereas 432 patients revealed a MitraScore ≥4 (29.0%). One-year mortality was significantly lower in patients with nonrelevant residual MR (MitraScore ≤3 14.6% vs MitraScore≥4 22.1%). An almost linear relationship between intraprocedural MitraScore after TEER and mortality was observed. The combined clinical endpoint of mortality and rehospitalization within the 1-year follow-up was also significantly lower in the MitraScore ≤3 group (31.5%) than in the MitraScore ≥4 group (40.8%). A subgroup analysis confirmed the predictive value of the MitraScore in patients with primary, secondary, or mixed MR etiologies. ConclusionsResidual MR assessed by intraprocedural MitraScore after TEER predicts 1-year mortality and rehospitalization. Therefore, the multimodal MitraScore improves MR assessment during mitral TEER and might improve patient survival.(A Prospective Registry Study on 1-Year Mortality and the Prognostic Significance of MitraScore After MitraClip Implantation in Patients With Mitral Regurgitation [MITRA-PRO]; DRKS00012288)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.