Abstract

In this paper, the inter-turn short circuit fault detection in permanent magnet synchronous machines (PMSM) using an open-loop physics-based back electromotive force (EMF) estimator is presented. The back EMF estimator is designed based upon a current mode tracking scheme. The thermal and saturation aspects of the machine are considered in the design of the estimator. The design procedure and stability criteria of the estimator are presented in detail. The fault detection is carried out based on the difference between the estimated back EMF and a reference back EMF. A 0.8 (kW) PMSM is studied experimentally as well as numerically under different inter-turn fault and operational contingencies. The numerical modeling is accomplished by a finite-element-based model coupled with the thermal network and polluted with inter-turn fault. The acceptable agreement between the simulated and experimental result validates the modeling process. The back EMF estimator fault detection system is led to discriminative inter-turn fault signatures in a fraction of second for wide speed range even in the presence of harmonic loads and dynamic eccentricities.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call