Self-absorption describes a pathological tendency towards the internal mental world (internalization) that often conflicts with the accurate monitoring of the external world. In performance monitoring, an augmented electrophysiological response evoked by internal signals in patients with anxiety or depressive disorder seems to reflect this tendency. Specifically, the error-related negativity (Ne/ERN), an index of error processing based on internal signals, is larger in patients compared to controls. In the present experiment, we investigated whether the preferential processing of internal signals in patients is linked to diminished and inflexible external signal processing. To this end, the electrophysiological response evoked by external signals was analysed in patients with panic disorder and healthy controls. Participants performed a choice-response task, where informative or uninformative feedback followed each response, and a passive viewing task. As a replication of previous studies, patients presented an augmented Ne/ERN, indexing enhanced processing of internal signals related to errors. Furthermore, the vertex positive potential (VPP) evoked by visual stimuli was larger in patients than in controls, suggesting enhanced attention to external signals. Moreover, patients and controls showed similar sensitivity to the feedback information content, indicating a normal flexibility in the allocation of monitoring resources to external signals depending on how informative these signals are for performance monitoring. These results suggest that the tendency towards internal signals in patients with panic disorder does not hinder the flexible processing of external signals. On the contrary, external signals seem to attract enhanced processing in patients compared to controls.
Highlights
A balanced processing of the internal mental world and the external world is a key aspect for everyday well-being
We employed electrophysiological recordings in an experimental context of performance monitoring to test whether patients with a psychological disorder characterised by internalization present a deficit in the flexible processing of internal and external signals and whether the tendency towards internal signals hinders the accurate processing of external signals
We investigated whether, within a context of performance monitoring, a focus towards the processing of internal signals in panic disorder, that should be evident as augmented Ne/ERN, leads to a reduced and inflexible processing of external signals
Summary
A balanced processing of the internal mental world and the external world is a key aspect for everyday well-being. We employed electrophysiological recordings in an experimental context of performance monitoring to test whether patients with a psychological disorder characterised by internalization (i.e. panic disorder) present a deficit in the flexible processing of internal and external signals and whether the tendency towards internal signals hinders the accurate processing of external signals. To this end, we employed an experimental design where participants could evaluate their performance in a response-choice task based on self-generated signals or feedback. This experiment enabled the analysis of potential differences in the flexible and accurate processing of internal and external signals between patients and controls as modulations of the error-related negativity (Ne/ERN; [4, 5]), an index of internal monitoring, and the N170/VPP complex [6], an index of attention on external visual stimuli [7]
Published Version (
Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have