Abstract

This report summarizes the structural and thermal transient deformation analysis of the Intermediate Size Inducer Pump. The analyses were performed in accordance to the requirements of N266ST310001, the specification for the ISIP. Results of stress analysis indicate that the thermal transient stress and strain are within the stress strain limits of RDT standard F9-4 which was used as a guide.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.