Abstract

Seven carbomer 934 lots exhibiting no appreciable differences in IR spectra, density or carboxylic acid group content were found to differ significantly as regards the rheological characteristics of their aqueous dispersions. These differences are attributed to differences in mean molecular weight, and explain significant differences between the two most dissimilar lots as regards the dissolution profiles of theophylline and hydrochlorothiazide tablets in which they were used as matrices.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.